POLARIS P17/50i 50KW

POLARIS P17/50i 50KW WIND TURBINE

 

Polaris turbines are exceptionally versatile and can be configured to fit an array of applications. With industry best power to output ratio, the turbine design strives for simplicity.

 

Rated at 53kw the Polaris P17/50i is an american built turbine. With a cut in speed of 2.7m/s and its permanent magnet generator it is ideal for domestic, schools, agricultural & commercial installations(Tower heights 24m, 30m & 36.6m)

 

• Direct drive generator (No gearbox or belts)

• Designed to IEC 61400-01 and 02 standards

• Very efficient in medium and low wind

• For Single Phase and Three Phase

• Very low maintenance

 

Annual output: up to 208,000kwh

20 year FIT Rate (2011): 25.3p/kwh

Minimum Electric Rate (2011): 3.1p

Annual Income: up to £62,000

Payback: from 3 years 

 

 


 

Specification Chart


ParameterValueUnit of Measurement
Rated Power 53.0 kW
Rotor Diameter 16.5 (54.1) m (ft)
Rated Wind Speed 11 (24.60) m/s (mph)
Cut-In Speed 2.7 (6.0) m/s (mph)
Cut-Out Speed 25.0 (55.9) m/s (mph)
Start Up Torque 40 kgf*m
Rated Torque 400 kgf*m
Survival Speed 59 (132) m/s (mph)
Operational RPM 68 rpm
Weight 6,443 (14,200) Kg (lb)
Std. Operating Temp. -10 to 40 (14to104) °C (°F)

 


 

Power Curve

 

power curves-50kW Polaris Turbine

 


 

 

General Specifications

 

General Turbine Design Features

 

General ConfigurationDescription
Type Horizontal Axis, Upwind
Design Class IEC Class II  (air density 1.225 kg/m3, average annual wind below 8.5m/s, 50-yr peak gust below 59.5m/s)
Design Life 20 Years
Drive TrainDescription
Generator Type Permanent Magnet (PM)
Type Direct Drive
Speed RegulationDescription
Generator Torque Control from Drive
Yaw System Description
Controls Active, Electromechanically driven with the wind direction / speed sensors and automatic cable unwind
Control/ElectricalDescription
Mounting Off Nacelle / Mounted, wired, tested and programmed in NEMA rated 3R enclosure
Compliant UL 1741, IEEE 1547
Power Converter VFD (Variable Frequency Drives)
Braking Systems Description
Emergency Back Up Speed Regulation Regenerative Brake
Loss of Grid Power / DC Buss Overvoltage Dynamic Resistive Brake
Emergency Shutdown / Parking Dual Caliper Disc Brake
TowerDescription
Mono Pole / Tubular Sectional / Flanged
Hydraulic tilt up design - Optional up to 100ft
Environmental StandardsDescription
Temperature Range -10°C to 40°C (-4°F to 104°F) – Standard
-25°C to 50°C (-13°F to 122°F) – Extreme Temperature Range